Can I feed 240 VAC service into the MX 400 cabinet?

Product applicability: MX Series: R920-MX, R829-MX, R247-MX, CHEVRON-MX and WWD-MX equipped with the MX 400 AC cabinet.

What this article is for

This article explains how to convert an MX 400 AC cabinet from 120 VAC to 240 VAC service.

About 240 VAC service in the MX 400 cabinet

The MX 400 AC cabinet is factory prepped and set up for 120 VAC input when your system is configured for AC power. To use 240 VAC service, the stock single pole breaker (ABB ST201M-C4) must be replaced with a two pole breaker, such as the ABB ST202M-C4 or equivalent.

MX 400 Stock Breaker (1P) New Breaker (2P)
MX 400 cabinet Stock single pole breaker New two pole breaker

Steps

  1. Remove the wiring at the bottom of the power supply.
  2. Remove the wiring and the stock breaker (ABB ST201M-C4).
  3. Replace it with a two pole breaker, such as the ABB ST202M-C4 or equivalent.
  4. Add wires to the bottom of each breaker pole, connecting them to the AC input (bottom) of the power supply.
  5. Proceed with wiring the cabinet for 240 VAC.

Ensure this procedure is completed by a qualified electrician. Follow your local electrical guidelines.

Labelling will no longer be accurate and is representative of 120 VAC only. Recommend changing the white neutral wire for black.


Need more help?

Carmanah Technical Support

Phone:1-877-722-8877

Email: techsupport@synapse-its.com

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.