The ratings depend on your power module. The table below shows the AC power supply fuse or breaker and the power module board fuses for each system.

| System | AC Power Supply Fuse/Breaker | Power Module Board |
|---|---|---|
| MX 100 Solar |
|
2x 15 A MINI blade Littelfuse 0297015.WXT |
| MX 200 Solar |
|
2x 15 A MINI blade Littelfuse 0297015.WXT |
| MX 300 Solar |
|
2x 15 A MINI blade Littelfuse 0297015.WXT |
| MX 300 AC |
1x 4 A glass cartridge Littelfuse 0313004.HXP |
1x 15 A MINI blade Littelfuse 0297015.WXT |
| MX 400 Solar |
|
2x 15 A MINI blade Littelfuse 0297015.WXT 2x 15 A ceramic cartridge¹ Littelfuse 0314015.HX |
| MX 400 AC | 4 A breaker |
1x 15 A MINI blade Littelfuse 0297015.WXT |
¹MX 400 solar systems have supplemental terminal block fuses in addition to the power module board fuses.