Can I provide my own wiring for MX systems?
Product applicability: MX Series: R920-MX, R829-MX, R247-MX, CHEVRON-MX and WWD-MX.
What this article is for
This article explains the option to provide your own bulk wiring for your MX Series system, and the cable requirements to follow.
About wiring in MX systems
MX systems were designed for simple, flexible field wiring. The cables have specific insulation colors that match the color code markings on the modules' spring-cage terminals, which offer a reliable connection without the need for crimped terminals. Cut-and-stripped cables are available in several common lengths. Bulk cable is also available for installers who prefer to tailor each cable length individually.
If you wish to use your own cable, use the table below. We recommend in all cases using only tinned, stranded copper wire rated for the application according to all applicable building and electrical codes.

| Function | Conductors and gauge | Stock wiring color |
|---|---|---|
| Push button | 2-conductor, 20 AWG | White/Green |
| Talking push button | 6-conductor, 20 AWG | White/Green/Red/Black/Blue/Brown |
| Pedestrian sensor or radar | 6-conductor, 20 AWG | White/Green/Red/Black/Blue/Brown |
| MX module-to-module | 4-conductor, 18 AWG | Yellow/White/Red/Black |

Steps
- Find your function in the table above (push button, talking push button, pedestrian sensor or radar, or module-to-module).
- Select a cable with the matching number of conductors and gauge. Use only tinned, stranded copper wire rated for the application.
- Match the insulation colors of your cable to the color code markings on the modules' spring-cage terminals.
- Connect each conductor to its matching spring-cage terminal.
Related articles
Need more help?