How can I connect a third-party trigger to my Carmanah MX Series beacon system?
Product applicability: MX Series: R920-MX and R247-MX.
What this article is for
This article explains how to connect a third-party trigger, such as a signalized intersection, sensor or detector, to activate your MX Series beacon system.
About third-party triggers
MX Series beacon systems can accept a dry contact from a third-party system or device for activation purposes. The dry contact must be able to accept 12-15 VDC, which will be present at the connection terminals. A third-party output can come from a variety of things, such as signalized intersections, sensors or detectors.
If a dry contact output is not available, you will need to use an isolation relay. Carmanah can provide this relay, or you can integrate your own that is appropriately specified.
DC to DC relay specifications
- Input: 4 VDC to 32 VDC
- Load: 5 VDC to 200 VDC
Output from an AC powered trigger will need an AC input/DC output relay.
Steps
- Check whether your third-party device has a dry contact output that can accept 12-15 VDC.
- If it does not, install an isolation relay (provided by Carmanah, or your own with the specifications above). For an AC powered trigger, use an AC input/DC output relay.
-
Wire the dry contact, or the output of the relay, to INPUT +/- of the TRIGGER terminals.

Wire termination for the trigger is not polarity sensitive.