How do I wire the Polara iNX/iDX into my E/F/G Series system?

This article details the wiring for the Polara iNX/iDX push button into a compatible Carmanah system.

Product applicability

The following products are discussed in this article:

  • E Series: R920-E and R820-E
  • F Series: R920-F and R820-F
  • G Series: SC315-G and R820-G

Please see the image below for wiring in the Polara iNX or iDX push button:

E/F Series G Series

E/F Series systems are prewired by Carmanah and only require termination to the button. If you are retrofitting the Polara iNX/iDX button into an existing compatible system please see our guide here.

The G Series has exposed terminal blocks where Carmanah may or may not provide the push button wire harness.

For retrofitting opportunities please see our article here

PWR/GND terminals at the iNX/iDX button will be filled with dielectric grease. Terminate wires with grease installed to prevent corrosion.

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.